This device is an interface to increase the performance of the 2-wire system between the door station and the handset. It also serves for video signal regeneration and 200m distance extension, increasing the number of devices that can be connected to the BUS and the use of up to three cascaded interface modules. It is a 4 DIN modular housing system.
Allows to increase the number of internal stations in the house up to 10.
The system must be physically configured. It has to be installed with 2-wire power supply and audio/video node or with compact power supply.
Power supply from SCS BUS: 18 to 27 V DC Power dissipation:2.25 W (max.) Temperatura de funcionamiento: 5 a 40 °C Consumo: Terminal IN (configuration MOD = 0) Consumption in standby: 30 mA Maximum consumption in operation:30 mA IN terminal (configuration MOD = 2 - MOD = 7) Consumption in standby:20 mA Maximum consumption in operation: 30 mA Terminal IN (configuration MOD = 5 - MOD = 6) Standby consumption: 5 mA Maximum power consumption in operation:30 mA Terminal OUT (configuration MOD = 0) Consumption in standby:50 mA Maximum power consumption in operation: 50 mA Terminal OUT (configuration MOD = 2 - MOD = 7) Consumption in standby: 30 mA Maximum consumption in operation:50 mA Terminal OUT (configuration MOD = 5 - MOD = 6) Consumption in standby:15 mA Maximum power consumption during operation: 50 mA